Parameter
None.
Remarks
The number of output groups refers to the number of preset voltage/current
groups in each cycle.
The total number of groups in timing output = the number of output groups ×
repetition cycle; wherein, you can send
:TIMEr:CYCLEs
to set the repetition cycle.
The power supply terminates the timer function when the total number of
groups is complete. At this point, the state of the power supply is decided by the
setting in
:TIMEr:ENDState
.
Return Format
The query returns an integer between 1 and 512, for example, 25.
Examples
:TIME:GROUP:NUM? /*Queries the number of output groups. The query
returns 25.*/
4.12.5 TIMEr:GROUP:INDEx
Syntax
TIMEr:GROUP:INDEx <
val
>
TIMEr:GROUP:INDEx?
Description
Sets or queries the index number of the group currently edited in the Arb editor.
Parameter
Name Type Range Default
<val> Integer 1 to 512 -
Remarks
If there is no data inserted in the current row, it automatically goes to the last group
of data in the editor.
Return Format
The query returns the index number of the group currently edited, for example, 25.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
103

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals