Page #122 background image
Remarks
The total number of points refers to the number of groups of parameters created
based on the template currently selected.
When the total number of points (denoted by P) and the number of current
output groups (denoted by G,
:TIMEr:GROUPs:NUM?
) are different, P groups of
parameters will be created using the template; then, the number of output
groups will change to P automatically.
Return Format
The query returns an integer between 1 and 512, for example, 80.
Examples
:TIME:TEMP:POINT 80 /*Sets the total number of points to 80.*/
:TIME:TEMP:POINT? /*Queries the total number of points currently
set. The query returns 80.*/
4.12.19 :TIMEr:TEMPlet:RISERate
Syntax
:TIMEr:TEMPlet:RISERate <
value
>
:TIMEr:TEMPlet:RISERate?
Description
Sets or queries the rise index of ExpRise.
Parameter
Name Type Range Default
<value> Integer 0 to 10 0
Remarks
When the template currently selected is ExpRise (
:TIMEr:TEMPlet:SELect
), the
parameters set cannot reach the maximum due to the characteristic of the
exponential function itself. The range of the parameters created is related to the rise
index currently set. The larger the rise index is, the wider the range of the parameters
will be.
Return Format
The query returns an integer between 0 and 10, for example, 5.
Command System
114
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals