EasyManua.ls Logo

Rigol DP2000 Series - Output:ocp:clear

Rigol DP2000 Series
145 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Name Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
Overcurrent protection (OCP) indicates that the output is disabled automatically
when the actual output current reaches the OCP level.
You can send
:OUTPut:OCP:CLEar
to clear the OCP event that occurred on the
specified channel.
If <source> is omitted, the command queries the output mode of the current
channel.
Return Format
The query returns 1 or 0.
Examples
:OUTP:OCP:QUES? CH1 /*Queries whether an OCP event occurred on
CH1.*/
4.8.5 :OUTPut:OCP:CLEar
Syntax
:OUTPut:OCP:CLEar [<
source
>]
Description
Clears an overcurrent protection (OCP) event occurred on the specified channel.
Parameter
Name
Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
Before executing the command, make sure to remove the condition that caused
the overcurrent protection on the specified channel (you can either decrease the
output current to below the OCP level or increase the OCP level to above the
output current).
If <source> is omitted, the command clears an OCP event occurred on the
current channel.
You can also send
[:SOURce[<n>]]:CURRent:PROTection:CLEar
to clear an OCP
event that occurred on the specified channel and enable the channel output.
Command System
48
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Related product manuals