Return Format
The query returns the voltage of the specified channel, for example, 7.500.
Examples
:VOLT 7.5 /*Sets the voltage to 7.5 V for the current channel.*/
:VOLT? /*Queries the voltage for the current channel. The query
returns 7.500.*/
4.9.8 [:SOURce[<n>]]:VOLTage[:LEVel]
[:IMMediate]:STEP[:INCRement]
Syntax
[:SOURce[<
n
>]]:VOLTage[:LEVel][:IMMediate]:STEP[:INCRement] {<
voltage
>|
<
def
>}
[:SOURce[<
n
>]]:VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]? [<
def
>]
Description
Sets or queries the step size of voltage for the specified channel.
Parameter
Name Type Range Default
<n> Integer {1|2|3} -
<voltage> Real
0 to the maximum voltage value
of the specified channel
Please refer to
Remarks
<def> Discrete {DEFault} -
Remarks
If [:SOURce<n>] is omitted, the command sets the corresponding parameter of
the channel currently selected.
<voltage> is the step size specified. DEFault is the default value. The default
values of <voltage> are shown in the table below:
Channel
Default
CH1 0.001 V
CH2 0.001 V
CH3 0.001 V
Command System
64
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals