4.8.11 :OUTPut:OVP:CLEar
Syntax
:OUTPut:OVP:CLEar [<
source
>]
Description
Clears an overvoltage protection (OVP) event occurred on the specified channel.
Parameter
Name
Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
Before executing the command, make sure to remove the condition that caused
the overvoltage protection on the specified channel (you can either decrease the
output voltage to below the OVP level or increase the OVP level to be greater
than the output voltage).
If <source> is omitted, the command clears an OVP event that occurred on the
current channel.
You can also send
[:SOURce[<n>]]:VOLTage:PROTection:CLEar
to clear an OVP
event that occurred on the specified channel and enable the channel output.
You can send
:OUTPut:OVP:QUES?
or
:OUTPut:OVP:ALAR?
to query whether an
OVP event has occurred on the specified channel.
Return Format
None.
Examples
:OUTP:OVP:CLE CH1 /*Clears an OVP event that occurred on CH1.*/
4.8.12 :OUTPut:OVP[:STATe]
Syntax
:OUTPut:OVP[:STATe] [<
source
>,]<
bool
>
:OUTPut:OVP[:STATe]? [<
source
>]
Description
Sets or queries the on/off state of the overvoltage protection (OVP) function of the
specified channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
53

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals