4.1.7 :ANALyzer:TYPE
Syntax
:ANALyzer:TYPE <
type
>
:ANALyzer:TYPE?
Description
Sets or queries the type of analysis.
Parameter
Name Type Range Default
<type> Discrete {COM|CURR} COM
Remarks
You can send this command to select common analysis (COM) or pulse current
analysis (CURR).
Return Format
The query returns COM or CURR.
Examples
:ANALyzer:TYPE CURR /*Sets the analysis type to pulse current
analysis.*/
:ANALyzer:TYPE? /*Queries the analysis type. The query returns
CURR.*/
4.2 :APPLy Commands
:APPLy command is the most straightforward method to program the power supply
via remote interfaces. For multi-channel models, you can select the specified channel
and set the voltage and current in a single command. If the setting values are within
the parameter ranges of the corresponding channel or range of the specified model,
the output voltage and current will change to the setting values immediately after this
command is executed. The range and default value of voltage/current corresponding
to each channel of DP2031 are shown in the table below.
Table 4.9 Ranges and default values of voltage/current corresponding to each
channel of DP2031 series
Channel (Range)
Voltage/Current
Available Range
Voltage/Current
Default Value
DP2031 Range1 CH1 0 V~32 V/0 V~3 A 0 V/0.1 A
Command System
18
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals