EasyManuals Logo

Rigol DP2000 Series Programming Guide

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Remarks
The overvoltage protection (OVP) function disables the output automatically
when the actual output voltage reaches the OVP level.
If <source> is omitted, the command queries whether an OVP event occurred on
the current channel.
You can send
:OUTPut:OVP:CLEar
to clear the OVP event that occurred on the
specified channel.
Return Format
The query returns 1 or 0.
Examples
:OUTP:OVP:ALAR? CH1 /*Queries whether an OVP event occurred on
CH1.*/
4.8.10 :OUTPut:OVP:QUES?
Syntax
:OUTPut:OVP:QUES? [<
source
>]
Description
Queries whether an overvoltage protection (OVP) event occurred on the specified
channel.
Parameter
Name
Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
The overvoltage protection (OVP) function disables the output automatically
when the actual output voltage reaches the OVP level.
If <source> is omitted, the command queries whether an OVP event occurred on
the current channel.
You can send
:OUTPut:OVP:CLEar
to clear the OVP event that occurred on the
specified channel.
Return Format
The query returns 1 or 0.
Examples
:OUTP:OVP:QUES? CH1 /*Queries whether an OVP event occurred on
CH1.*/
Command System
52
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals