EasyManuals Logo

Rigol DP2000 Series Programming Guide

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Parameter
Name Type Range Default
<value> Integer 0 to 100 50
Remarks
Symmetry is specified as the ratio of the duration of the rising edge within a period to
the whole period.
Return Format
The query returns the symmetry, for example, 60%.
Examples
:TIME:TEMP:SYMM 60 /*Sets the Symmetry to 60%.*/
:TIME:TEMP:SYMM? /*Queries the Symmetry. The query returns 60%.*/
4.12.22 :TIMEr:TEMPlet:WIDTh
Syntax
:TIMEr:TEMPlet:WIDTh <
value
>
:TIMEr:TEMPlet:WIDTh?
Description
Sets or queries the Positive Pulse Width of Pulse.
Parameter
Name Type Range Default
<value> Real Up to 3600 s 1 s
Remarks
Pulse width refers to the duration of high level within a period.
The actual available range of <value> is related to the period currently set
(
:TIMEr:TEMPlet:PERIod
). The positive pulse width cannot be larger than the
period.
Return Format
The query returns a real number, for example, 14.000.
Command System
116
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals