EasyManua.ls Logo

Rigol DP2000 Series - Idn; Opc

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Return Format
The query returns a decimal value, which corresponds to the binary-weighted sum of
the bits to be enabled in the enable register of the Standard Event register. For
example, the query might return 20.
Examples
*ESE 20 /*Enables bit2 (query error) and bit4 (execution error) in
the enable register of the Standard Event register.*/
*ESE? /*Queries the enabled bits in the enable register of the
Standard Event register. The query returns 20.*/
4.3.4 *IDN?
Syntax
*IDN?
Description
Queries the instrument’s identification string.
Parameter
None.
Remarks
None.
Return Format
The query returns the ID string in the format of Rigol Technologies,<model>,<serial
number>,<software version>.
<model>: the model number.
<serial number>: the serial number.
<software version>: the software version.
4.3.5 *OPC
Syntax
*OPC
*OPC?
Description
Sets the bit0 (OPC, “Operation Complete” bit) of the Standard Event register after
the command is executed.
Queries whether all the previous commands are executed.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.