EasyManuals Logo

Rigol DP2000 Series Programming Guide

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Return Format
The query returns a decimal value, which corresponds to the binary-weighted sum of
the bits to be enabled in the enable register of the Standard Event register. For
example, the query might return 20.
Examples
*ESE 20 /*Enables bit2 (query error) and bit4 (execution error) in
the enable register of the Standard Event register.*/
*ESE? /*Queries the enabled bits in the enable register of the
Standard Event register. The query returns 20.*/
4.3.4 *IDN?
Syntax
*IDN?
Description
Queries the instrument’s identification string.
Parameter
None.
Remarks
None.
Return Format
The query returns the ID string in the format of Rigol Technologies,<model>,<serial
number>,<software version>.
<model>: the model number.
<serial number>: the serial number.
<software version>: the software version.
4.3.5 *OPC
Syntax
*OPC
*OPC?
Description
Sets the bit0 (OPC, “Operation Complete” bit) of the Standard Event register after
the command is executed.
Queries whether all the previous commands are executed.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
23

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals