EasyManua.ls Logo

Rigol DP2000 Series Programming Guide

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Examples
:OUTPut:PAIR SERies /*Connects CH1 and CH2 in series (internal).*/
:OUTPut:PAIR? /*Queries the connection mode. The query returns
SERIES.*/
4.8.15 :OUTPut[:STATe]
Syntax
:OUTPut[:STATe] [<
source
>,]<
bool
>
:OUTPut[:STATe]? [<
source
>]
Description
Sets or queries the on/off state for the specified channel.
Parameter
Name Type Range Default
<source> Discrete {CH1|CH2|CH3|ALL} -
<bool> Bool {0|1|ON|OFF} 0
Remarks
Before enabling the channel output, please make sure that the current setting
will not affect the devices connected to the power supply.
If <source> is omitted, the command executes the corresponding operation on
the current channel.
Return Format
The query returns 1 or 0.
Examples
:OUTP CH1,ON /*Enables the output for CH1.*/
:OUTP? CH1 /*Queries whether the CH1 output is enabled. The query
returns 1*/
4.8.16 :OUTPut:TRACk[:STATe]
Syntax
:OUTPut:TRACk[:STATe] <
bool
>
:OUTPut:TRACk[:STATe]?
Description
Sets or queries the on/off state of tracking function.
Command System
56
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
Voltage Resolution1 mV
Current Resolution1 mA
TypeProgrammable DC Power Supply
Output Channels1, 2
Output Voltage Range0-30V
Current Accuracy0.1% + 5mA
Ripple & Noise (CC)≤3 mArms
InterfaceUSB, LAN
Display4.3 inch LCD