EasyManua.ls Logo

Rigol DP2000 Series - Output:ocp:alar; Output:ocp:ques

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Examples
:OUTP:MODE? CH1 /*Queries the current output mode of CH1. The query
returns CV.*/
4.8.3 :OUTPut:OCP:ALAR?
Syntax
:OUTPut:OCP:ALAR? [<
source
>]
Description
Queries whether an overcurrent protection (OCP) event occurred on the specified
channel.
Parameter
Name
Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
Overcurrent protection (OCP) indicates that the output is disabled automatically
when the actual output current reaches the OCP level.
You can send
:OUTPut:OCP:CLEar
to clear the OCP event that occurred on the
specified channel.
If <source> is omitted, the command queries the output mode of the current
channel.
Return Format
The query returns 0 or 1.
Examples
:OUTPut:OCP:ALAR? CH1 /*Queries whether an overcurrent protection
(OCP) event occurred on CH1.*/
4.8.4 :OUTPut:OCP:QUES?
Syntax
:OUTPut:OCP:QUES? [<
source
>]
Description
Queries whether an overcurrent protection (OCP) event occurred on the specified
channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
47

Table of Contents

Other manuals for Rigol DP2000 Series

Related product manuals