:OUTP:MODE? CH1 /*Queries the current output mode of CH1. The query
returns CV.*/
4.8.3 :OUTPut:OCP:ALAR?
Syntax
:OUTPut:OCP:ALAR? [<
source
>]
Description
Queries whether an overcurrent protection (OCP) event occurred on the specified
channel.
Parameter
Name
Type Range Default
<source> Discrete {CH1|CH2|CH3} -
Remarks
Overcurrent protection (OCP) indicates that the output is disabled automatically
when the actual output current reaches the OCP level.
You can send
:OUTPut:OCP:CLEar
to clear the OCP event that occurred on the
specified channel.
If <source> is omitted, the command queries the output mode of the current
channel.
Return Format
The query returns 0 or 1.
Examples
:OUTPut:OCP:ALAR? CH1 /*Queries whether an overcurrent protection
(OCP) event occurred on CH1.*/
4.8.4 :OUTPut:OCP:QUES?
Syntax
:OUTPut:OCP:QUES? [<
source
>]
Description
Queries whether an overcurrent protection (OCP) event occurred on the specified
channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
47

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals