EasyManuals Logo

Rigol DP2000 Series Programming Guide

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
4.12.15 :TIMEr:TEMPlet:MINValue
Syntax
:TIMEr:TEMPlet:MINValue {<
value
>|
MINimum
|
MAXimum
}
:TIMEr:TEMPlet:MINValue? [
MINimum
|
MAXimum
]
Description
Sets or queries the minimum voltage or current value of the template currently
selected.
Parameter
Name Type Range Default
<value> Real
Voltage or current range of the
channel currently selected
0
Remarks
When the object (
:TIMEr:TEMPlet:OBJect
) is set to Voltage (V), this command sets
the minimum voltage value; when the object is set to Current (C), this command
sets the minimum current value.
When the selected template is Pulse, this command sets or queries the low level.
“MINimum” and “MAXimum” indicate the minimum and maximum current/
voltage available.
Return Format
The query returns the minimum voltage or current value of the template currently
selected, for example, 0.200 or 0.1000.
Examples
:TIME:TEMP:OBJ C,1.5 /*Sets the object to current and the voltage
value to 1.5 V.*/
:TIME:TEMP:MINV 0.1 /*Sets the minimum current to 0.1 A for the
selected template.*/
:TIME:TEMP:MINV? /*Queries the minimum current for the template
currently selected. The query returns 0.1000.*/
4.12.16 :TIMEr:TEMPlet:OBJect
Syntax
:TIMEr:TEMPlet:OBJect <
obj
>[,<
value
>|
MINimum
|
MAXimum
]
:TIMEr:TEMPlet:OBJect? [
MINimum
|
MAXimum
]
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
111

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals