EasyManua.ls Logo

Rigol DP2000 Series - Timer:templet:minvalue; Timer:templet:object

Rigol DP2000 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.12.15 :TIMEr:TEMPlet:MINValue
Syntax
:TIMEr:TEMPlet:MINValue {<
value
>|
MINimum
|
MAXimum
}
:TIMEr:TEMPlet:MINValue? [
MINimum
|
MAXimum
]
Description
Sets or queries the minimum voltage or current value of the template currently
selected.
Parameter
Name Type Range Default
<value> Real
Voltage or current range of the
channel currently selected
0
Remarks
When the object (
:TIMEr:TEMPlet:OBJect
) is set to Voltage (V), this command sets
the minimum voltage value; when the object is set to Current (C), this command
sets the minimum current value.
When the selected template is Pulse, this command sets or queries the low level.
“MINimum” and “MAXimum” indicate the minimum and maximum current/
voltage available.
Return Format
The query returns the minimum voltage or current value of the template currently
selected, for example, 0.200 or 0.1000.
Examples
:TIME:TEMP:OBJ C,1.5 /*Sets the object to current and the voltage
value to 1.5 V.*/
:TIME:TEMP:MINV 0.1 /*Sets the minimum current to 0.1 A for the
selected template.*/
:TIME:TEMP:MINV? /*Queries the minimum current for the template
currently selected. The query returns 0.1000.*/
4.12.16 :TIMEr:TEMPlet:OBJect
Syntax
:TIMEr:TEMPlet:OBJect <
obj
>[,<
value
>|
MINimum
|
MAXimum
]
:TIMEr:TEMPlet:OBJect? [
MINimum
|
MAXimum
]