RIGOL Chapter 2 Command System
2-90 DSA800E Programming Guide
:READ:ACPower?
Syntax
:READ:ACPower?
Description
Execute an adjacent channel power measurement and return the measurement results.
Explanation
The power unit of the return values is the same with the current Y-axis unit.
This command will select data from the latest measurement results and transmit the data to the output
buffer.
Return Format
The query returns 5 values (main channel power, upper channel power as well as the power difference
between the upper channel and main channel (in dBc), the lower channel power as well as the power
difference between the lower channel and the main channel (in dBc)) in scientific notation (separated by
commas). For example, -5.150423E+01,-5.173441E+01, -2.301865E-01,-5.142665E+01,7.757568E-02.
:READ:ACPower:LOWer?
Syntax
:READ:ACPower:LOWer?
Description
Execute an adjacent channel power measurement and return the lower channel power.
Explanation
The power unit of the return value is the same with the current Y-axis unit.
This command will select data from the latest measurement results and transmit the data to the output
buffer.
Return Format
The query returns the lower channel power in scientific notation. For example, -5.142665E+01.
:READ:ACPower:MAIN?
Syntax
:READ:ACPower:MAIN?
Description
Execute an adjacent channel power measurement and return the main channel power.
Explanation
The power unit of the return value is the same with the current Y-axis unit.
This command will select data from the latest measurement results and transmit the data to the output
buffer.
Return Format
The query returns the main channel power in scientific notation. For example, -5.150423E+01.