RIGOL Chapter 2 Command System
2-152 DSA800E Programming Guide
:SOURce Subsystem
Command List:
:SOURce:CORRection:OFFSet
:SOURce:POWer:LEVel:IMMediate:AMPLitude
:SOURce:TRACe:REF:STATe
:SOURce:TRACe:STORref
Explanation:
The :SOURce commands are only available for DSA832E-TG.
:SOURce:CORRection:OFFSet
Syntax
:SOURce:CORRection:OFFSet <rel_ampl>
:SOURce:CORRection:OFFSet?
Description
Set the offset of the output amplitude of the tracking generator.
Query the offset of the output amplitude of the tracking generator.
Parameter
Name
Type
Range
Default
<rel_ampl>
Integer
-200 dB to 200 dB
0 dB
Return Format
The query returns the offset in scientific notation.
The amplitude offset changes the power readout of the tracking generator but does not change the actual
output power of the tracking generator.
Example
The command below sets the offset to 10 dB.
:SOURce:CORRection:OFFSet 10
The query below returns 1.000000E+01.