RIGOL Chapter 2 Command System
2-52 DSA800E Programming Guide
:FETCh:ACPower:MAIN?
Syntax
:FETCh:ACPower:MAIN?
Description
Query the main channel power of adjacent channel power measurement.
Explanation
This command is only available when the adjacent channel power measurement is enabled.
The power unit of the return value is the same with the current Y-axis unit.
This command will select data from the latest measurement results and transmit the data to the output
buffer.
Return Format
The query returns the main channel power in scientific notation.
Example
The query below returns -5.150423E+01.
:FETCh:ACPower:MAIN?
:FETCh:ACPower:UPPer?
Syntax
:FETCh:ACPower:UPPer?
Description
Query the upper channel power of adjacent channel power measurement.
Explanation
This command is only available when the adjacent channel power measurement is enabled.
The power unit of the return value is the same with the current Y-axis unit.
This command will select data from the latest measurement results and transmit the data to the output
buffer.
Return Format
The query returns the upper channel power in scientific notation.
Example
The query below returns -5.173441E+01.
:FETCh:ACPower:UPPer?