Clock Synthesis
R&S
®
SMA100B
281User Manual 1178.3834.02 ─ 05
Remote command:
:CSYNthesis:OFFSet:STATe on page 427
DC Offset
Sets the value of the DC offset for both clock synthesis signal outputs.
Remote command:
:CSYNthesis:OFFSet on page 427
Voltage
For Output Type = "CMOS", sets the high-level of the output signal.
Remote command:
:CSYNthesis:VOLTage on page 428
Delta Phase
Shifts the phase of the generated clock signal.
Remote command:
:CSYNthesis:PHASe on page 428
Reset Delta Phase Display
Resets the parameter Delta Phase.
User Variation
Defines and activates a user-defined step width for varying the frequency or level with
the rotary knob.
If disabled, the step width varies in steps of one unit at the cursor position.
Variation Active ← User Variation
Activates the set user-defined step width.
Remote command:
:CSYNthesis:FREQuency:STEP:MODE on page 429
:CSYNthesis:POWer:STEP:MODE on page 429
Variation Step ← User Variation
Sets the user-defined step width.
Remote command:
:CSYNthesis:FREQuency:STEP on page 429