123
Editing a Sample
 
REV (Reverse)
 
When the sample has been played back from the End point to 
the Start point, it will be repeatedly played back in the reverse 
direction, from the Loop Start point to the Start point.
 
fig.15-007
 
REV-ONE (Reverse One-shot)
 
The sample will be played back only once from the End point to 
the Start point in the reverse direction.
 
fig.15-008
 
By pressing OUTPUT knob, you can audition the sample sound. 
Press the knob once again to stop playback.
 
If you hold down OUTPUT knob and edit the start/loop/end 
point, the sample will play repeatedly across that point. Since 
the sound in the region you’re specifying will play repeatedly, 
this is a convenient way to check your setting.
(Zooming-in or zooming-out on the waveform will change the 
region that loops.)
 
Sample modify operations (Chop, Normalize, etc.) apply to the 
entire sample. Even if you specify a start point or end point, 
they will be ignored. If you want to apply the operation only to 
the region between the start point and end point, use Truncate 
to delete unwanted portions of the sample, and then perform 
the sample modifying operation.
Here you can make various settings for the sample.
 
1.
 
In the Sample List screen, select the sample that you want 
to edit.
 
2.
 
Press [MENU].
 
The Sample Utility screen will appear.
 
3.
 
Use   or   to select “Sample Parameter.”
 
4.
 
Press [ENTER].
 
The Sample Parameter screen will appear.
 
fig.15-009
 
Alternatively, you can access the Sample Parameter screen from 
the Sample Edit screen by pressing [MENU] to get the Sample 
Utility, choosing “Sample Parameter” from the menu, and 
pressing [ENTER].
 
5.
 
Use   or   to select the parameter and turn the VALUE 
dial or use [INC][DEC] to get the value you want.
 
•
 
Loop Tune
 
Specifies the pitch of the loop region.
 
Value:
 
-50– +50
 
* Make fine adjustments in one-cent (1/100 semitone) increments.
 
•
 
Original Key
 
Note number that will play the sample at the pitch at which it 
was sampled.
 
Value:
 
0 (C-1)–127 (G9)
 
You can also specify the key by playing a note on your external 
MIDI keyboard.
•
 
BPM (TEMPO)
 
Specifies the original tempo of the sample.
To set the BPM (tempo), you can press and turn the VALUE 
dial, or press the VALUE dial and use [INC][DEC] to adjust the 
value below the decimal point.
 
Value:
 
5.00–300.00
 
* In order to synchronize the tempo, Wave Temp Sync (p. 55) must be 
turned on.
 
•
 
Time Stretch Type
 
Specifies how the tempo will be synchronized. Decreasing this 
value will optimize the sound for more rapid phrases, and 
increasing this value will optimize the sound for slower 
phrases.
 
Value:
 
TYPE01–TYPE10
•
 
Start Fine
 
Fine adjustment of the Start point.
 
Value:
 
0–255
Start P.
Loop
Start P.
End P.
Start P.
Loop
Start P.
End P.
 
Making Settings for Sample 
(Sample Parameters)
Fantom-XR_r_e.book 123 ページ 2006年4月4日 火曜日 午前10時14分