Operating instructions Distance measuring device DL100 – CANopen®
Operation at the measuring device
42 © SICK AG • Subject to change without notice • 8015416/ZPN2/2017-09-08
8 Operation at the measuring device
Damage to operation
ATTENTION!
Damage to the buttons by incorrect handling!
Incorrect handling of the keys may damage the keys.
Operationismadedicultorimpossiblebythis.
Therefore:
• Onlyoperatekeyswithyourngersorapointer.
• Do not operate buttons with pointed or hard objects.
8.1 Measured value display
Once the measuring device is supplied with voltage, the display will indi-
cate the current measurement value.
8.2 Choose parameter
Choose a menu, a parameter or an option using the keys and . The
menu path is indicated in the respective chapter.
→ For the entire menu structure, see page 137, chapter 16.
8.3 Choose option
1. Use the keys and to select the desired parameter.
2. Use the key
or to select the desired option.
3. Perform one of the following steps:
• Push the key
to save the changes.
• Push the key
to cancel the process. The parameter name is
displayed again.
4. Perform one of the following steps to return to the measured value
display:
• Push the key
until the measured value is displayed again.
• Wait for approx. 2 minutes. The display automatically switches back
to measured value display without operation of a key. Any settings
made are also saved.