NOTE
If y
ou use mounting kit 2b and install the system plug with angled plug connectors on
the rear side of the safety laser scanner, the following assembly sequence is recom‐
mended:
1. Mount the holding plate and alignment bracket on the mounting surface.
2. Mount cables with M12 plug connectors to the system plug and lay the cables.
3. Install the mounting bracket and safety laser scanner on the alignment bracket.
4. Install the system plug on the safety laser scanner.
Tool required:
T
X20 Torx wrench
Figure 50: Mounting using mounting kit 2
1
Mounting bracket
2
Screws for mounting bracket
3
Threaded holes for mounting bracket
4
Alignment bracket
5
Screws for alignment bracket
6
Holding plate
7
Screws for holding plate
8
Centering pin
9
Holding tab
ß
Drill holes with countersink
à
Outer drill holes
á
Stabilization screw (only bracket 2b)
MOUNTING 5
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
69
Subject to change without notice