7.14 Measurement data output
For measurement data output, the baud rate of the interface needs to be configured.
T
he Silent time defines the time, after sending the silent byte, for which the continuous
output of data can be interrupted to make it possible to access to the interface. The
factory default setting for the silent time is 5,000 ms.
Possible configurations for the Silent time:
The Silent time is automatically set to 5,000 ms.
The Silent time is customized to a shorter value between 60 and 4,980 ms.
The Send mode option is used to configure whether the measurement data output is to
be triggered as a Continuous data output or Data output only on request.
For further details on this topic, see the “Telegram Listing Standard” documentation
(part no. 9090807).
CMS functionality
On t
he S300 Expert, further parameters, in addition to those described above, can be
configured for the CMS functionality.
The Send mode option is used to configure whether the measurement data output is to
be triggered as a Continuous data output, Data output only on request or by an Internal event.
If Internal event is selected, this event must be defined.
With Continuous data output, the data to output must be selected.
If Measurement data output is also enabled, it is necessary to select whether the measure‐
ment data are to be output together with the I/O data in one telegram or in two separate
telegrams.
For the measurement data output, one to five segments, which are defined by start and
end angles, need to be specified.
For further details on this topic, see the “Telegram Listing CMS” documentation (part
no. 9090806).
7 C
ONFIGURATION
102
O P E R A T I N G I N S T R U C T I O N S | S300 8010948/ZA21/2020-06-18 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m