EasyManuals Logo

SICK S300 Series User Manual

SICK S300 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
150 mm
150 mm
190 mm
110 mm
1
1
Figure 38: Fitting height
1
Set protective field length
NOTE
Y
ou can also mount the device upside down in order to achieve the optimal scan plane.
4.4 Integration in electrical control
4.4.1 Connection diagrams
Important information
WARNING
Ineffectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
Downstream contactors must be positively guided and monitored depending on regula‐
tions applicable at the operation site or required reliability of the safety function.
b
Make sure that downstream contactors are monitored (external device monitoring,
EDM).
4 PROJECT PLANNING
50
O P E R A T I N G I N S T R U C T I O N S | S300 8010948/ZA21/2020-06-18 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m