To protect the protective device against inadvertent adjustment or manipulation, you
mus
t use the contour of the surroundings as a reference for the safety laser scanner.
Further topics
"Using the contour as a reference", page 92
4.3.6.1 Minimum distance
Overview
F
or hazardous point protection, a minimum distance must be maintained between the
protective field and the hazardous point. This minimum distance ensures that the haz‐
ardous point can only be reached once the dangerous state of the machine has been
stopped completely.
S
1
Figure 33: Minimum distance to hazardous area
1
Contours as reference
4 PROJECT PLANNING
44
O P E R A T I N G I N S T R U C T I O N S | S300 8010948/ZA21/2020-06-18 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m