Maximum protective field range
40 mm (hand detection) 1.60 m
50 mm (leg detection) 2.10 m
70 mm (leg detection) 3.00 m
150 mm (body detection) 3.00 m
Complementary information
NOTE
Y
ou can configure the warning field up to 8 m for all resolutions. The detection capabil‐
ity within the warning field depends on the radiance factor of the objects to be
detected.
Further topics
"Char
acteristic curves", page 128
7.6.2 Basic response time
The basic response time of the safety laser scanner is 80 ms.
NOTE
Y
ou may need to add supplements to the basic response time due to multiple sampling
and data transmission over EFI.
Further topics
"R
esponse times", page 129
7.6.3 Maximum protective field range
The maximum protective field range of the safety laser scanner, which depends on the
conf
igured resolution and the variant used, is shown in the CDS.
NOTE
The maximum protective field range of the device must be sufficient to cover the calcu‐
lated protective field size including the necessary supplements.
Further topics
"R
esolution", page 78
"Protective field size", page 38
7.7 Incremental encoder
The S300 Professional and the S300 Expert have two dual-channel dynamic control
in
puts using which the possible monitoring cases can be switched depending on the
speed.
Incremental encoders must be connected to the dynamic control inputs for this pur‐
pose. Per incremental encoder, one 0°/90° output is required so that the direction of
travel can be determined.
To use the inputs A and B as dynamic control inputs, select the Indicate velocity option.
CONFIGURATION 7
8010948/ZA21/2020-06-18 | SICK O P E R A T I N G I N S T R U C T I O N S | S300
79
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m