b
S
witch off the voltage supply for the device for at least 2 seconds and then switch
it back on.
Or:
b
Restart the device using the CDS.
10.4 Advanced diagnostics
The supplied CDS (Configuration & Diagnostic Software) contains extended diagnostic
op
tions. The CDS enables you to isolate the problem if the error situation is unclear or
there are availability issues.
For detailed information, see the online help of the CDS (Configuration & Diagnostic
Software).
TROUBLESHOOTING 10
8010948/ZA21/2020-06-18 | SICK O P E R A T I N G I N S T R U C T I O N S | S300
119
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m