EasyManuals Logo

SICK S300 Series User Manual

SICK S300 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
1 2
Figure 8: Safety laser scanner with two monitoring cases on one AGV
1
Monitoring case 1, low speed, field set 1
2
Monitoring case 2, high speed, field set 2 with larger protective fields and warning fields
3.2.8 Interoperability
The safety laser scanner can be integrated into an EFI system. An EFI system can com‐
pr
ise two safety laser scanners, one sens:Control device with one or two safety laser
scanners, or one Flexi Soft safety controller with up to four safety laser scanners.
The Flexi Soft safety controller supports two EFI strings to which up to two safety laser
scanners (S3000, S300, S300 Mini, or mixed) each can be connected. They can there‐
fore be used to implement applications with up to four safety laser scanners.
3 P
RODUCT DESCRIPTION
20
O P E R A T I N G I N S T R U C T I O N S | S300 8010948/ZA21/2020-06-18 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m