EasyManuals Logo

SICK S300 Series User Manual

SICK S300 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
NOTE
W
hen mounting the device, observe the dimensional drawings.
Further topics
"Dimensional dr
awings", page 135
5.2.4 Information label Notes on daily check
b
Af
ter mounting the device, affix the supplied Notes on daily check information
label.
NOTE
Use onl
y the information label in the language that the operators of the
machine can read and understand.
Affix the information label so that it is clearly visible to all operators during
operation of the system. After attaching additional objects and equipment,
the information label must not be concealed from view.
MOUNTING 5
8010948/ZA21/2020-06-18 | SICK O P E R A T I N G I N S T R U C T I O N S | S300
63
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Series and is the answer not in the manual?

SICK S300 Series Specifications

General IconGeneral
Scanning angle270 °
Number of monitoring cases4
Protection classIP65
Number of scanning planes1
Angular resolution0.5°
InterfaceRS-422, Ethernet
Supply voltage24 V DC
Ambient operating temperature0 °C ... +50 °C
Laser class1 (IEC 60825-1)
Storage temperature–25 °C ... +70 °C
Protective field range0.1 m to 3 m