Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function Manual
464 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
3. Test of the SI function "Safe Brake Control (SBC)"
Required when using Basic and/or Extended Functions
You do not need to prepare trace recording for this test.
4. Test of the SI function "Safe Stop 2" (SS2)
Only required when used in Extended Functions
This test is also required if you are not explicitly using SS2 but just one function for
which STOP C occurs as an error response.
Alternatively, you can also carry out the quantitative test using STOP C yourself, if you
use the table from section Acceptance test for Safe Stop 2 (Ex
tended Functions)
(Page 486).
Trace recordi
ng is required
5. Test of the SI function "Safe Operating Stop" (SOS)
Only required when used in Extended Functions
This test is also required if you are not explicitly using SOS, but just one function for
which STOP D or STOP E occurs as an error response.
Alternatively, you can also carry out the qualitative test using STOP C, STOP D or
STOP E yourself, if you use the table from section Acceptance test for Safe Operating
Stop (SOS) (Page 489).
Trace recordi
ng is required
6. Test of the SI function "Safely Limited Speed" (SLS)
Only required when used in Extended Functions
A trace recording is required for each SLS limit
7. Test of the SI function "Safe Direction" (SDI)
Only required when used in Extended Functions
Trace recordings are required for each stop response used
8. Test of the SI function "Safe Speed Monitor" (SSM)
Only required when used in Extended Functions
Trace recording is required
C) Functional testing of forced dormant error detection
Testing the forced dormant error detection of the safety functions for each control type.
1. Test of the forced dormant error detection of the safety function on the drive
If you are using Basic Functions, you need to activate and then deactivate STO once
again.
If you are using Extended Functions, you need to carry out a test stop.

Table of Contents