Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
487
No. Description Status
Analyze trace:
4.
SOS is triggered after the SS2 timer (p9352/9552) has expired.
5. Save/print the trace and add it to the acceptance report (refer to the example below)
Deselect SS2
Ensure that the drive is running with the setpoint again
6.
No Safety faults and alarms (r0945[0...7], r2122[0...7], r9747[0...7])
Example Trace SS2
'HVHOHFW66
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGFXUUHQW6%5VSHHGOLPLWRQ&RQWURO8QLW
%LWWUDFNV
626DFWLYH
66DFWLYH
Figure 8-40 Example Trace SS2