Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
499
No. Description Status
5. Save/print the trace and add it to the acceptance report (refer to the example below)
Deselect SLS and acknowledge Safety messages
Ensure that the drive is running with the setpoint again
6.
No Safety faults and alarms (r0945[0...7], r2122[0...7], r9747[0...7])
Example trace SLS with STOP C
6723&DFWLYH
6HOHFW6/6ELW
6HOHFW6/6ELW
'HVHOHFW6/6
%LWWUDFNV
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGFXUUHQW6%5VSHHGOLPLWRQ&RQWURO8QLW
,QWHUQDOHYHQW
6/6DFWLYH
66DFWLYH
$FWLYH6/6OHYHOELW
$FWLYH6/6OHYHOELW
626DFWLYH
Figure 8-44 Example trace: SLS with STOP C