Communication
9.2 Communication according to PROFIdrive
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
555
POS_ZSW1 (status word 1, positioning mode, r0108.4 = 1)
See function diagram [2466].
Table 9- 21 Description of POS_ZSW1 (status word 1, positioning mode, r0108.4 = 1)
Bit Meaning Remarks Parameter
0 Active traversing block, bit 0 BO: r2670.0
1 Active traversing block, bit 1 BO: r2670.1
2 Active traversing block, bit 2 BO: r2670.2
3 Active traversing block, bit 3 BO: r2670.3
4 Active traversing block, bit 4 BO: r2670.4
5 Active traversing block, bit 5
Active traversing block (6-bit counter)
BO: r2670.5
6 Reserved
7 Reserved
8 STOP cam minus active 1 BO: r2684.13
9 STOP cam plus active 1 BO: r2684.14
1 Jog active 10 Jog active
0 Jog not active
BO: r2094.0
BO: r2669.0
1 Reference point approach active 11 Reference point approach active
0 Reference point approach not active
BO: r2094.1
BO: r2669.1
1 Flying referencing 12 Flying referencing
0 Flying referencing not active
BO: r2684.1
1 Traversing blocks active 13 Traversing blocks active
0 Traversing blocks not active
BO: r2094.2
BO: r2669.2
1 Set-up active 14 Set-up active
0 Set-up not active
BO: r2094.3
BO: r2669.4
1 MDI active 15 MDI active
0 MDI not active
BO: r2670.15
XIST_A
Actual position value is displayed
Normalization: 1 corresponds to 1 LU