Basic information about the drive system
10.1 Parameter
Function Manual
656 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
The CDS and DDS can be switched over during normal operation. Further types of data set
also exist, however these can only be activated indirectly by means of a DDS changeover.
● EDS Encoder Data Set
● MDS Motor Data Set
''6'ULYHGDWDVHW
&'6&RPPDQGGDWDVHW
'ULYH
'DWDVHWLQGHSHQGHQW
GULYHSDUDPHWHUV
0RWRUVHOHFWLRQ
(QFRGHUVHOHFWLRQ
(QFRGHUVHOHFWLRQ
('6(QFRGHUGDWDVHW
0'60RWRUGDWDVHW
Figure 10-2 Parameter categories
Saving parameters in a non-volatile memory
The modified parameter values are stored in the volatile RAM. When the drive system is
switched off, this data is lost.
So that the changes can be restored, the data must be saved as follows in a non-volatile
manner in the Control Unit.
● Save parameters - device and drive
p0977 = 1; automatically reset to 0
● Save the parameters with STARTER
See "Copy RAM to ROM" function
NOTICE
The power supply to the Control Unit may first be switched off after saving has finished
(i.e. after saving has started, wait until it has finished and parameter p0977 has the