6
01/2008 "Program" operating area
6.8 Program simulation
6
© Siemens AG 2008 All rights reserved.
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition 6-327
Abort
OK
Return to main simulation menu. The old settings before the setting
screen was selected are retained.
Return to main simulation menu. The modified settings are saved and
activated immediately.
Basic "Settings..."
Blank
Active view
Blank dimension cuboid
Program control
- Milling: without model (display area), cuboid (blank dimension
cuboid), cylinder (blank dimension cylinder).
- Turning: without model (display area), cylinder (blank dimension
cylinder) and active processing diameter for peripheral surface.
- Milling: X-Y, Z-X, Y-Z (for "Cuboid" and "Without model" only)
- Turning: Z-X always defined, cannot be changed
- Minimum and maximum dimensions for each axis
- SKP: Skip blocks (10 skip levels are available)
- M01: Programmed STOP 1 or
- M101: Programmed STOP 2 taken into account
- Single block mode:
SBL1: Stop after each machine function
SBL2: Stop after each block
SBL3: Stop in cycle
- Display all blocks or only traversing blocks
Tool data (source) NC active
data
The tool offsets are used in accordance with the active NC (Match tool
data \TO_INI.INI) and the tool path is simulated with graphic tools.
With technology turning the cutter radius is not modeled. The tool
radius compensation is evaluated. Tools that are not interpreted are
displayed as polymarkers.
With tool
HMI data, local TOA data, global SPF file, tool match data from data
management \DP.DIR\SIM.DIR\TO_INI.INI
Default tools
Evaluation only with milling/drilling if no TO_INI.INI
(Match tool data) is present and tool management option not active.
The tool diameter can be parameterized (providing access is enabled
via a valid password) if ON is activated under the Options settings.
The tool radius compensation is evaluated.
Without tool data
The tool path is simulated with a polymarker. No evaluation of tool
radius compensation i.e. broken-line graphics with compensation
value D0.