8
01/2008 Diagnostics operating area
8.5 Calling theversion screen
8
© Siemens AG 2008 All rights reserved.
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition 8-419
8.5.3 Cycle version output
Function
You can save the contents of the version displays for cycles in a
separate log file.
Sequence of operations
Service
displays
Versions
Cycle
version
Save
versions
To create a separate log file for the following version contents, press
the "Save versions" vertical softkey in the "Version data type cycles"
version display:
File: Type:
CYP.COM Package overview
CYP_DET.COM Details
ALLCYCLE.COM All cycles
CUS.COM User cycles
CMA.COM Manufacturer cycles
CST.COM Standard cycles
When the data have been saved, the following message appears:
"File stored!" "
Ö Services:\Diagnostics\LogFiles\xxx.com.
xxx stands for the file name preceding the extension .COM for
each type.
8.5.4 Displaying loadable compile cycles
Function
Loadable compile cycles (CC) are an optional extra. The functionality
must be enabled explicitly. If loadable compile cycles are available on
your NCK, you can display them in a separate "Version data cycles"
display under Service displays/Version/Compile cycles.
Sequence of operations
Loadable compile cycles
Service
displays
Compile cycles are loaded when you initiate an NCU reset and can
then be displayed under Service displays/Version/Compile cycles.