2
Operator Components/Operating Sequences 01/2008
2.2 Machine control panel (MCP)
2
©Siemens AG 2008 All rights reserved.
2-38 SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
This function is dependent on the settings under "Program control" in
the Machine operating area.
Reset
Reset
When you press the <Reset> key:
• Execution of the current part program is aborted.
• Messages issued by the monitoring function are deleted (except
the alarms POWER ON, NC Start and "Acknowledge alarm").
• The channel is set to "Reset" state, i.e.,
− The NC control remains synchronized with the machine.
− The control is in its initial state and ready for a new program
run.
References /FB/ K1, Description of Functions BAG, Channel, Program control.