140
Ginlong
Connect the inverters to each other
•
Wiring using Ginlong‘s daisy chain cable.
•
Where to connect: COM round socket on the inverter.
Procedure:
1. Insert the RJ45 connector into the first inverter‘s COM3 socket.
2. Insert the other end of the cable into the COM2 socket on second inverter.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter according to the inverter manufacturer‘s instructions.
Assign the communication address
•
Recommendation: Continuous numbering starting with 1.
•
Default settings on the inverter: Communication address 1.
•
Setting: Using the inverter‘s operating display.
•
Procedure: Start according to the inverter manufacturer‘s instructions.
.
New supported models (as of firmware 4.2.1):
•
Solis-5K-4G, Solis-6K-4G, Solis-8K-4G, Solis-9K-4G, Solis-10K-4G, Solis-12K-4G, Solis-15K-4G, Solis-17K-4G, Solis-
20K-4G, Solis-5K-4G-LV, Solis-10K-4G-LV, Solis-25K-4G, Solis-30K-4G, Solis-33K-4G, Solis-40K-4G
New supported models (as of firmware 4.2.2):
•
Solis-15K-LV, Solis-20K-LV, Solis-25K-LV, Solis-30K-LV, Solis-1P4K-4G, Solis-1P5K-4G, Solis-1P7K-4G, Solis-1P8K-
4G, Solis-1P9K-4G, Solis-1P10K-4G, Solis-Mini-700-4G, Solis-Mini-1000-4G, Solis-Mini-1500-4G, Solis-Mini-
2000-4G, Solis-Mini-2500-4G, Solis-Mini-3000-4G