Safety
2–2
DOC-06810 Rev. A
Safety Features
Objet1000Plus3Dprintersareequippedwiththefollowingsafetyfeatures:
InterlockSwitch ThepowersuppliedtotheUVlampandthe
motionmotorsisturnedoffwhenthe doorsare
opened.
WARNING:Donotdefeat(override)the
interlockswitch.Doingsocouldresult in
seriouspersonalinjury.Iftheinterlockswitch
doesnotfunctioncorrectly,donotusethe
printer,andcontact
yourservi ceprovider.
SafetyLock Thedoorsarelockedwhiletheprinteris
working.Thelockisreleasedwhentheprinter
revertstopauseorstopmode.
WARNING:Donotdefeat(override)the
safetylock.Doingsocouldresultinserious
personalinjury.
Ifthesafetylockdoesnotfunctioncorrectly,do
notusetheprinter,andcontactyourservi c e
provider.
UVScreening Thetransparentsectionofthedoorsblocks
harmfulUVradiation,allowingtheoperatorto
viewthemodelasitisbeingmade.
CircuitBreaker Thepowertotheprinteristurnedoffincaseof
electricalovercurrent.
Note: The circuit breaker is only accessible to
service personnel.
UVLamp
Overheating
Protection
ThepowersuppliedtotheUVlampandthe
motionmotorsisturnedoffifthetemperature
aroundthelampreaches90°C(194°F).
AlabelontheUVlampcoverindicatesifthe
temperaturehasexceeded65°C(150°F).
GroundedChassis Thechassisoftheprinterisgrounded,
to
preventelectricalshock.
Note: The power outlet must be properly
grounded, in accordance with the local
electric code, to provide this protection.
EmergencyStop Emergencystopswitchesarelocatedonthe
frontandbackoftheprinter.
Important: Pushing the emergency stop
switch disconnects power to the motors
only. This switch does not disconnect the
power supply to the printer; printer
circuits remain live.