Operating & Maintaining the Objet1000 Plus 3D Printer
6–26
DOC-06810 Rev. A
Figure 6-28: Sample Pattern Test
6. Carefullyinspectthetestpapertoseeiftherearemissinglines.
Toomanymissinglines,especiallyiftheyareinthesamearea,
indicatesthatthequalityofprintingwhenproducingmodelswillbe
poor.Ifthisisthecase,see“ImprovingPrintQuality,”below.
Note: Acceptable model quality is subjective, and depends on the type
and scale (size) of the models produced. As a rule, however, more than 10
missing lines in one area of a column is considered unacceptable.
Improving
Print Quality
Ifyoususpectthatprintqualityispoor,performthepatterntest(see
“PatternTestonpage 25).Iftheresultsarepoor,usethefollowing
proceduretoimproveprintquality.
If the results of the last pattern test are poor:
1. FromtheOptionsmenu,selectPurge Sequence,orpressF4.
2. Intheconfirmationdialogbox,click
Yes.
TheprintheadsarepurgedofModelandSupportmaterial,andthe
wiperremovesexcessmaterialfromthem.
3. Repeatthepurgesequence.
4. Performthepatterntest.
If the results of the pattern test are still poor:
1. Manuallycleantheprintheads(see“CleaningthePrintHeads,Roller
andWiperonpage 21).
2. Performthepurgesequence.
3. Performthepatterntest.
If the results of the pattern test are still poor:
1. Carefullycleantheprintheadsagain,makingsurethereisnoresidue
leftonthem.
2. Performthepurgesequence.
3. Performthepatterntest.
If the results of the pattern test are still poor:
¾
Optimizetheprintheadsandreplacefaultyprintheads,ifnecessary
(see“Optimizing(Calibrating)PrintHeads”onpage 36).