Date printed: 12.11.03 SW V 4.0 Diagnostics 14-5
Snapshot Controller (cont.)
104 Information yes yes Mic Setting not recalled due to corrupted Mic Setting Data!
105 Information yes yes Snapshot not loaded because user [%s] (owner of the
Snapshot) is not defined on this mixing console!
106 Information yes yes Mic Setting not loaded because user [%s] (owner of the Mic
Setting) is not defined on this mixing console!
107 Information yes yes All Private Mic Settings used.- Only [n] of [m] Private Mic
Settings loaded!
108 Information yes yes Recall not possible as selected Snapshot is not defined!
109 Information yes yes Recall not possible as selected Mic Setting is not defined!
110 Information yes yes Snapshot recall failure - channel [n] not available for insert
assignment! Insert [m] not recalled.
PC-Card Controller
Error ID Type Indication Diag. Box Error Text (Conflict)
113 Information yes yes PC-Card Slot [%] - Empty!
114 Information yes yes PC-Card Slot [%] - Card not supported!
115 Information yes yes PC-Card Slot [%] - Card not formatted!
116 Information yes yes PC-Card Slot [%] - File not found!
117 Information yes yes PC-Card Slot [%] - Card already formatted!
118 Information yes yes PC-Card Slot [%] - Card write protected!
119 Information yes yes PC-Card Slot [%] - Please wait, formatting in progress!
120 Information yes yes PC-Card Slot [%] - Card formatted!
121 Information yes yes PC-Card Slot [%] - Card write error, IFX errorcode = [n]
122 Information yes yes PC-Card Slot [%] - Card read error, IFX errorcode = [n]
123 Information yes yes PC-Card Slot [%] - Volume not mounted, no IFX workspace.
124 Information yes yes PC-Card Slot [%] - Volume not mounted, bad BIOS Pa-
rameter Block.
127 Information yes yes PC-Card Slot [%] - File Empty!
128 Information yes yes PC-Card Slot [%] - Snapshot Block Checksum Failure! [n] of
[m] Snapshots loaded.
129 Information yes yes PC-Card Slot [%] - Mic Setting Block Checksum Failure! [n]
of [m] Mic Settings loaded.
130 Information yes yes PC-Card Slot [%] - Configuration Checksum Failure! Con-
figuration not loaded.
131 Information yes yes PC-Card Slot [%] - Snapshot Block Software Version
mismatch!
132 Information yes yes PC-Card Slot [%] - Mic Setting Block Software Version
mismatch!
133 Information yes yes PC-Card Slot [%] - Configuration Software Version mis-
match!
134 Information yes yes PC-Card Slot [%] – SW Update Prolib Version mismatch!
SW not loaded.
136 Information yes yes PC-Card slot [%] - Channel Routing Block Checksum failure!
[n] of [m] Channel Routings loaded.
137 Information yes yes PC-Card slot [%] - Channel Routing Block software version
mismatch!
138 Information yes yes PC-Card slot [%] - SW update central Module firmware
incompatibility! Software not loaded.
Flash Programming
Error ID Type Indication Diag. Box Error Text (Conflict)
144 Error yes yes Flash: Sector is protected. AMD error code = [n]
145 Error yes yes Flash: Programming failure. Addr = [adr], prevData = [x],
newData = [y], AMD error code = [n]
146 Error yes yes Flash: Erase failure. AMD error code = [n]
147 Error yes yes Flash: Odd address invalid with word access
148 Error yes yes Flash: Memory access failed at address = [adr]
149 Error yes yes Flash: AMD error code = [n]
User Interface
Error ID Type Indication Diag. Box Error Text (Conflict)
176 Information yes no Due to insufficient memory the first 10 messages have been
removed from the loglist
Automation Interface
Error ID Type Indication Diag. Box Error Text (Conflict)
192 Warning yes no Communication to Broadcast Automation lost!
193 Information yes no Communication to Broadcast Automation established!