OnAir 2000M2 Digital Mixing Console
Date printed: 12.11.03 SW V4.0 Service Terminal 5-3
The following terminal settings must be used:
5.2 SW Update via the Service Terminal
Procedure 1. Dump all snapshots, mic settings, and configuration data to a PC-Card or
to the service terminal (refer to chapter “Dump mode”).
2. Connect the cable between the PC (COM1 or COM2) and the OnAir
2000M2 (“service terminal” on the controller board). For this, you have to
open the center section of the console by loosening five screws.
After pressing ENTER or switching the console on, you will see the
message
ServIf:\
on the terminal.
If you enter ? followed by ENTER, you will see a list of all possible debug
commands; refer to chapter 5.5
To download the new software you need to type
startdownload serviceterminal, followed by ENTER at the
prompt.
Then send the file OA2000.ABS as a text file.
This procedure will take about 10...15 min to complete the download.
3. Reload all snapshots, mic settings, and configuration data from the PC-
Card or the service terminal (refer to chapter “Dump mode”).