GTS Technical Manual
9. April 2021 Edition: V1.00/2021 6-41
Copyright © 2020, Diversey
ST.08.16 error codes overview - 2100_4000_5000_3500µicro_V1.40.fm
8015 (only BMS) Charger U time out Charging time for U phase (second phase) has been de-
tected as too long. The charging has been aborted.
Check charger, batteries, wires and connections.
Red LED for charger
is ON
8017 (only BMS) Charger over temperature Temperature of charger has been detected as too high.
The charging has been aborted.
Check ventilation, charger, batteries, wires and connec-
tions.
Red LED for charger
is ON
8019 (only BMS) Charger output short circuit On charger output a short circuit (over current) has been
detected.
Check batteries, wires and connections.
Red LED for charger
is ON
8020 (only BMS) Charger no load No current on output has been detected.
Check batteries, wires and connections.
Red LED for charger
is ON
90XX (only USB
stick)
Communication with USB
stick
These errors are only in combination when using a USB
stick to save data or install firmware.
If this error appears, please check USB stick.
Blocked 90XX
Error codes Function Control Machine status Display
informa-
tion
Table 4: Error codes overview

Table of Contents