MultiFlow Configuration of the MultiFlow
Enhanced protection
parameter
Modification of the parameter 3.1.4.5.0.2. Only after
entering the master password.
(version 5.02 and higher)
Activation of the no-load measurement
Minimum amount of product which needs to be
measured in the amount of time specified in 3.1.4.6.3
so that the delivery is found valid and continued.
(1…50 L)
Period in which the minimum quantity of product
(3.1.4.6.2) must be measured during idling, so that
the measurement is found valid and continued.
(1...300 s)
Period after which the product flow is terminated
automatically without any further active idle
measurement. (1 .180 s)
Status output in the History window. Helpful during
the configuration phase of the no-load measurement.
Activates special surcharge on the receipt.
Product code for special surcharge (e.g. transport
duty). Default can be changed by the user on site.
Activates/deactivates the billing option
(c.f. also 3.1.4.5.4):
0: no bill
1: bill based on gross prices
(with VAT incl.)
2: bill based on net prices
(without VAT)
Only for the English version of the program.
Parameter not active in German version.
Only for the English version of the program.
Parameter not active in German version.
Summary of all orders transmitted by the OBC on
one receipt