MultiFlow  Configuration of the MultiFlow
3.1.4.6.5
Info
M
3
0 (no)
Status output in the History window. Helpful during
the configuration phase of the no-load measurement.
3.1.4.7
---
3.1.4.8
Add Surcharge
M
3
0 (no)
Activates special surcharge on the receipt.
3.1.4.9
Default Surcharge
M
3
31
Product code for special surcharge (e.g. transport
duty). Default can be changed by the user on site.
The following description is only relevant to program versions of V5.03
and above (approval acc. to MID).
The function 'No-load measurement' is used for product measurement
and bypasses the MultiFlow control unit. It is used to measure any
dispensed volume of product while the MultiFlow unit is running, without
the MultiFlow controlling the dispensing volume. This measurement is
only indicated in V
T
[L] (at product temperature). Calculation of the
volume of product dispensed is based on the specified figure for 'Number
of pulses per liter' (parameter 3.3.1.1). Temperature compensation is not
performed.
To prevent the detection function from becoming 'nervous' and therefore
to prevent measuring errors from occurring, within a defined period of
time (parameter 3.1.4.6.3) a minimum volume of product (parameter
3.1.4.6.2) needs to be measured before the measurement can be found
to be valid and for the measuring process then to continue. Failure to
meet these criteria causes each measurement to be rejected. Any idle
speed measurement found to be valid will be terminated automatically as
soon as no further product can be found and measured within a definable
period of time (parameter 3.1.6.3.6.4). The measurement is also
terminated as soon as the MultiFlow unit is switched off. In this case,
when the MultiFlow unit is next switched on, an evaluation is performed
of the idle speed volume of product measured up to the time it was
switched off.
The measuring results of the idle speed measurement are recorded in the
logbook as 'IdleDrop' and are also listed in the event and tour reports. For
unambiguous identification of the idle speed volume of product, product
code '00' is used. In addition, for idle speed dispensing operations, order
number '9998' is used (uncontrolled, unplanned dispensing). No
assignment number is issued so none is displayed in any of the reports.
Data that is not available is marked as '-'. Individual details cannot be
altered by the user. In the following examples for event report, short
report and detailed report are listed, with two no-load measurements in
each of these three sub-reports.