MultiFlow  Configuration of the MultiFlow
change to discharge pre-selection. If no synchronization is possible, the
Wait screen can be left at the earliest after 90 seconds via the keys
START, STOP or ENTER, to make discharge possible in this case also
(without communication with the EMIS). Waiting for synchronization
between MultiFlow and EMIS can be deactivated via parameter
3.1.4.5.8.2.
See also See chapter Fehler! Verweisquelle konnte nicht gefunden
werden. "Fehler! Verweisquelle konnte nicht gefunden werden." /
page Fehler! Textmarke nicht definiert..
9.3.1.4.7
Notes on Billing
If it is necessary to present a bill in addition to the delivery note, the
billing parameter needs to be set at 1 (for a gross statement) or 2 (for a
net statement).
With the setting 0 only delivery notes are printed. The query regarding
the desired type of documentation that is otherwise made before
printout of a document is absent in this case.
Parameter 3.1.4.5.4 customer type query” makes it possible to choose
between “gross statement (private customers) and “net statement”
(business customers) after each discharge (see chapter 9.3.1.4.5
"Customer Type Query" / page 128).
In the UK there are different rates of tax when invoicing business
customers for heating oil. Since these regulations are not applicable in
Germany the parameters 3.1.4.0.2 and 3.1.4.0.3 only have a function in
the UK program version.
9.3.1.4.8
No-load Measurement
3.1.4.6
No-load
Measurement
(version 5.02 and higher)
3.1.4.6.1
Activate
Measurement
M
3
0 (nein)
Activation of the no-load measurement
3.1.4.6.2
Minimum amount
M
3
10
Minimum amount of product which needs to be
measured in the amount of time specified in 3.1.4.6.3
so that the delivery is found valid and continued.
(1…50 L)
3.1.4.6.3
Active Period
M
3
30
Period in which the minimum quantity of product
(3.1.4.6.2) must be measured during idling, so that
the measurement is found valid and continued.
(1...300 s)
3.1.4.6.4
Timeout
M
3
60
Period after which the product flow is terminated
automatically without any further active idle
measurement. (1 .180 s)