MultiFlow Configuration of the MultiFlow
Changes on CAN Bus parameters take effect only
after restart.
Node number (address) of the MultiFlow when
several devices are linked to one external CAN Bus.
0: No CAN communication
1: Node no. of the first MultiFlow.
Controls the printer (default mode).
2-31: Node no. of the subordinate devices
Controls the electronic termination of the CAN Bus.
Must be activated for the devices furthest apart at the
CAN-bus, e.g. TMC and second MultiFlow.
Node number of the TMC or on-board computer, if
this has been activated under 3.1.4.1 ”Operating
mode”.
Disables delivery data transfer after a delivery.
Transfer only possible via PRINT menu.
Activation of the output of bill of delivery on the
delivery receipt at orders received from the OBC.
Activation of the remote operation option
Node number of the base station of the remote
operation, if this has been activated.
9.3.1.8
Overfill prevention
Overfill prevention
at the service
station
Repeat rate of the overfill prevention signal. If the
signal fails the discharge is terminated with an OP
error.
Node number of the base station of the overfill
prevention if this has been activated under 3.1.8.8.
9.3.1.9
Dead man’s switch
Activation of the optional driver attention monitoring
device.
Repeat rate of the attention signal. If the signal fails
the discharge is terminated with a dead man error.
Node number of the base station of the monitoring
device, if the latter has been activated.