Sening
®
is a registered trademark of FMC Technologies
137
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
9.3.1.6
CAN-Bus (global)
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6
Global CAN-Bus
Changes on CAN Bus parameters take effect only
after restart.
3.1.6.1
Global Node No.
M
2
0
Node number (address) of the MultiFlow when
several devices are linked to one external CAN Bus.
0: No CAN communication
1: Node no. of the first MultiFlow.
Controls the printer (default mode).
2-31: Node no. of the subordinate devices
3.1.6.2
CAN-Termination
M
2
1 (yes)
Controls the electronic termination of the CAN Bus.
Must be activated for the devices furthest apart at the
CAN-bus, e.g. TMC and second MultiFlow.
3.1.6.3
OBC
3.1.6.3.1
OBC node
M
2
0
Node number of the TMC or on-board computer, if
this has been activated under 3.1.4.1 ”Operating
mode”.
3.1.6.3.2
Disable AutoTX
M
2
0 (no)
Disables delivery data transfer after a delivery.
Transfer only possible via PRINT menu.
3.1.6.3.3
Enhanced Document
Layout
M
2
0 (no)
Activation of the output of bill of delivery on the
delivery receipt at orders received from the OBC.
9.3.1.7
Remote operation
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6.4
Remote operation
3.1.6.4.1
Use remote operation
M
2
0 (no)
Activation of the remote operation option
3.1.6.4.2
Remote operation
node
M
2
0
Node number of the base station of the remote
operation, if this has been activated.
9.3.1.8
Overfill prevention
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6.5
Overfill prevention
at the service
station
3.1.6.5.1
Transmission interval
M
2
18 (sec/10)
Repeat rate of the overfill prevention signal. If the
signal fails the discharge is terminated with an OP
error.
3.1.6.5.2
OP node
M
2
0
Node number of the base station of the overfill
prevention if this has been activated under 3.1.8.8.
9.3.1.9
Dead man’s switch
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6.6
Dead man’s switch
3.1.6.6.1
Use dead man
M
2
0 (no)
Activation of the optional driver attention monitoring
device.
3.1.6.6.2
Transmission interval
M
2
18 (sec/10)
Repeat rate of the attention signal. If the signal fails
the discharge is terminated with a dead man error.
3.1.6.6.3
Dead man node
M
2
0
Node number of the base station of the monitoring
device, if the latter has been activated.