MultiFlow  Configuration of the MultiFlow
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.5.2
Receipt draining
M
2
0 (no)
(up to version 5.00)
Parameter currently not in use. In a future program
version will activate printout of a receipt after residue
removal.
3.1.8.5.1
Residue removal
control
M
2
1
(version 5.00 and higher)
1 : Off
2: Stand-alone
Activates a reminder concerning residue removal in
the event of product change.
3: EPE2-manual
As described under 2; however, the wet leg sensor
connected to the EPE2 monitors the residue removal.
No restart of MultiFlow required after residue removal.
4: EPE2-AIII
As described under 3; however, the "Autom. residue
removal" menu item (menu 8) includes the option to
control a pump for the measuring system residue
removal via the EPE2 output.
5: EPE2-AI
As described under 4; but due to the system, instead
of a pump, a valve is connected to the EPE2 which
gives the additional option of a product change
between AI and AIII products.
3.1.8.5.2
Residue removal
timeout
M
2
0 (no)
(version 5.00 and higher)
Timeout for the autom. draining of the measuring
system with the aid of the EPE2 in "EPE2 automatic"
mode. Residue removal stops automatically after this
period of time.
3.1.8.5.3
Residue removal
receipt
M
2
0 (no)
(version 5.00 and higher)
Parameter currently not in use. In a future program
version will activate printout of a receipt after residue
removal.
3.1.8.5.4
With product change
M
2
0 (no)
Residue removal query appears after each product
change, unless residue removal had previously been
detected.
3.1.8.6
---
No longer applicable from version 2.1 and higher;
see 3.1.8.4.3
3.1.8.7
Hose Set
Cal.
1
UVLB
Defines the hose paths that are used in the
measuring system for later selection.
B Bypass
D (L) Dry hose
G (S) Dry hose with Gravity discharge
P Pumped dry hose discharge
U Unmetered
W (V) Wet hose
Note: Each abbreviation may be used only
twice at the most.