MultiFlow  Configuration of the MultiFlow
9.3.1.15
Valve Control
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8
Valve control
3.1.8.1
Path Selection
Cal.
Basic control
Defines the structure of the measuring system used:
1. Basic control: Basic version with manual
operation of a control block and product release.
2. High/Low Flow: as above, but with reduction of
the flow at the start and end of the discharge.
3. Fully electronic: Control switch replaced by
electronical valve controller.
(not supported in current version)
4. Expanded electronical control: as described in 3.,
but combined with flow control (however, no
additive dosing possible).
5. With blow down (GB):
special control for GB, with flow control, additive
pump, blow down of the dry hose after the
discharge and product transfer / self loading.
6. Expanded electronical control: as described in 3.,
with flow control & additive dosing (no unmetered
discharge)
3.1.8.2
Turn-on Delay
M
2
3 (sec)
Delay on activating the control valve before the
release valve.
3.1.8.3
Turn-off Delay
M
2
3 (sec)
Delay on closing the release valve before the control
valve.
9.3.1.16
Flow Control
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.4
Flow Control
3.1.8.4.1
High Flow Rate ON
M
2
5.0 (liter)
Threshold for switchover from a reduced to a higher
flow rate:
Positive value: Amount in liters
Negative values: Flow rate in liters/min.
3.1.8.4.2
High Flow Rate OFF
M
2
20.0 (liter)
Remaining volume at which the switchover to reduced
flow rate takes place.
3.1.8.4.3
Wet Hose OFF
M
2
0.5 (liter)
Remaining volume at which the flow is stopped.
Used for all hoses, except for Dry Hose (G) or (P)
3.1.8.4.4
Dry Hose (G) OFF
M
2
0.5 (liter)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and Gravity discharge.
3.1.8.4.5
Dry Hose (P) OFF
M
2
1.5 (liter)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and pumped discharge.
3.1.8.4.6
Enable Adjustment
M
2
1 (yes)
Enables the automatic adjustment of
parameters 3.1.8.4.3 … 3.1.8.4.5
3.1.8.4.7
---
3.1.8.4.8
Start delay
M
3
0 m(sec.)
Delay time between hose selection and delivery start.
(0 .. 10s).
9.3.1.17
Draining
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.5
Draining
3.1.8.5.1
Drain control
M
2
0 (no)
(up to version 5.00)
Activates a reminder concerning residue removal in
the event of product change.