MN F09 002 US DOK-383E Issue/Rev. 3.65 (02/24)
MultiFlow Configuration of the MultiFlow
Defines the structure of the measuring system used:
1. Basic control: Basic version with manual
operation of a control block and product release.
2. High/Low Flow: as above, but with reduction of
the flow at the start and end of the discharge.
3. Fully electronic: Control switch replaced by
electronical valve controller.
(not supported in current version)
4. Expanded electronical control: as described in 3.,
but combined with flow control (however, no
additive dosing possible).
5. With blow down (GB):
special control for GB, with flow control, additive
pump, blow down of the dry hose after the
discharge and product transfer / self loading.
6. Expanded electronical control: as described in 3.,
with flow control & additive dosing (no unmetered
discharge)
Delay on activating the control valve before the
release valve.
Delay on closing the release valve before the control
valve.
Threshold for switchover from a reduced to a higher
flow rate:
Positive value: Amount in liters
Negative values: Flow rate in liters/min.
Remaining volume at which the switchover to reduced
flow rate takes place.
Remaining volume at which the flow is stopped.
Used for all hoses, except for Dry Hose (G) or (P)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and Gravity discharge.
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and pumped discharge.
Enables the automatic adjustment of
parameters 3.1.8.4.3 … 3.1.8.4.5
Delay time between hose selection and delivery start.
(0 .. 10s).
(up to version 5.00)
Activates a reminder concerning residue removal in
the event of product change.