1) The values stated apply to the factory setting of the standard product “Heating oil EL”
in the “DE” language version of the MultiFlow software. For all other products and
language variants, the factory setting of the listed product parameters is '0'.
Comparison must be made with chapter 7 "Product Definition" / page
95 !
9.10.1
Note regarding product group "Direct linear"
In order to comply with PTB specifications (April 11, 2011, business
reference PTB-1.5-4052004) relating to the temperature-volume
conversion of fuels based on mineral oil, bio-components and their
mixtures (e.g. Super E10), product group '6 Direct-Linear' (parameter
3.5.nn.7.3) must be selected for the products affected / involved. The
product-dependent parameters for this calculation ('Process 1') for
temperature range and density change factor must be defined in settings
under 3.5.nn 7.7.
Specified figures for the change-in-density factory acc to PTB
announcement (April 11, 2011, business reference PTB-1.5-4052004).
The values listed represent the change-in-density factors as of April 11,
2012.
S el ec ti on :3 5x x7
1 Co mp en sa ti on
2 Co mp .T em pe ra tur e
3 Co nv er sa ti on
4 Av er ag e De ns ity
5 Me te r Fa ct or s
6 Mi n. P ro du ct tem p.
7 De ns .c ha ng e fac t.