9.10.2
Notes on the hose set
When using electronic selection of the hose set, to increase the operating
safety and to minimize mixtures each product can be assigned to one (or
more) defined hose set(s).
The codes to be entered are identical with those for the entry of the hose
set which are available on the vehicle in parameter 3.1.8.7. (chapter
9.3.1.8
"Valve Control" / page 145).
The addition of a digit after a code serves as the selection between
several alternatives.
Example: UV1LB1
Meaning: The meter offers the following discharge passes
(chapter 6.4 "Electronic hose selection (optional)" /
page 78):
1.
Unmetered
2.
Wet hose 1
4.
Dry hose
5.
Bypass 1
9.10.3
Notes on scale prices
•
The MultiFlow offers the option to specify the product price depending
on the delivery quantity. The scale prices 1..5 are used for this (menu
3.5.nn.7.5.1 .. 3.5.nn.7.5.5).
•
Unlike the scale prices 2..5 the starting delivery quantity for "Scale
price 1" is defined as "0". If specifying only one price irrespective of
the delivery quantity, carry out the price specification only in "Scale
price 1". Set the scale price specifications 2..5 to "0".
•
For delivery quantity-dependent prices, specify the respective delivery
quantity and the associated product price in the "Scale price 2" to
"Scale price 5" menu items.
•
The delivery quantities must be in ascending order and unused scale
prices must be set to "0"!
9.10.4
Notes on minimum product temperature
You can specify the minimum product temperature using the product-
specific parameter 3.5.x.x.7.6. If product temperature drops below the
minimum threshold during delivery, delivery will be automatically
interrupted. You can specify a temperature range of -20°C to 20°C. This
function is deactivated if you enter 99 (default value).