Sening
®
is a registered trademark of FMC Technologies
181
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
Status information
Immediately after switching on, the current statuses of all sensor inputs
are detected and saved in the logbook.
Example:
SIStat: 01-------12---0 --- 0
SIIndx: 11-------22---5 --- 7
Sensor 1, 2: „Dome cover“ (1)
Sensor 10, 11: „API coupling“ (2)
Sensor 15: „Cabinet door left“ (5)
Sensor 20: „Handbrake“ (7)
It is possible to output a special event report via the print menu
(parameter 0.1.2) which contains only the sensor events.
9.13.2 Configuration of the device
9.13.2.1
Sensor interface
The sensor interface is configured via its DIP switches.
DIP switch
Function
1
Node Number
2
Node Number
3
Reset
4
Monitoring without ext. power
supply
Node Number
DIP 1
DIP 2
Node Number
OFF
OFF
6
ON
OFF
7
OFF
ON
8
ON
ON
9