EasyManua.ls Logo

TechnipFMC Sening MultiFlow - Page 176

TechnipFMC Sening MultiFlow
356 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
182
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
Reset
DIP 3
Function
OFF
No reset
ON
Reset after power on
Monitoring without external power supply
DIP 4
Function
OFF
Monitoring not possible
ON
Monitoring possible
The software is integrated into the used microcontroller. Should it be
necessary to replace the microcontroller, switch off the power supply
from the internal batteries. To do this, switch the DIP switch DIP 4 to
"OFF"!
9.13.2.2
MultiFlow
The basic parameters for configuration of the sensor module are
compiled under the menu item 3.1.6.9.
The sensors are divided into group sensors and individual sensors.
Individual sensors comprise only one sensor each whereas group
sensors comprise varying numbers of sensors depending on the
application. The size of such a sensor group is determined by the
“Compartment number” parameter (3.1.6.9.3).
Group sensors
Individual sensors
Dome cover
Cabinet door left
API coupling
Cabinet door right
Foot valve
Handbrake
In-line valve
Example:
A specified compartment number of “3” means that e.g. up to 3 dome
cover sensors can be used, however only one handbrake sensor is
supported.

Table of Contents

Related product manuals